- Control, indication, and motor voltage of the switch points are measured in real time and displayed on the LCD screen
- Real-time monitoring of eight track switch operation at the same time and the measured voltage is stored in the database inside the equipment for one month
- The Remote Monitoring PC monitors the status information of a number of track switch points simultaneously and stores it in the database for three months. And based on the information stored, the situation can be reproduced by providing play-back function
- If the voltage measured at the track switch points during monitoring is outside the normal operation range, it is alerted with visually and acoustically (sound and lamp)